Product Description
Alderon VersAlarm™ 4X Outdoor Rated Liquid Level Alarm System Panel
Take control of your liquid levels with the Alderon VersAlarm™ 4X, an outdoor rated 1-Zone tank alarm system. Engineered for optimal functionality, this alarm system features 120VAC power, making it a versatile choice for many outdoor liquid level monitoring applications. With its clear visual indicators, advanced auxiliary contacts, and a robust design, it serves as an essential tool for managing septic tanks, sump pits, holding tanks, pump chambers, and water tanks.
Product Features of the VersAlarm 4X Panel include:
Outdoor Rated System: Withstanding harsh weather conditions, this alarm is perfect for any outdoor setup.
Versatile Power Options: Runs on either 120VAC or 240VAC, to cater to your voltage requirements.
Green LED Indicators: Built-in LEDs provide clear, immediate alerts on the system's power status.
Two-Level Press-And-Hold Feature: Convenient option to disable LEDs when needed.
Battery Backup Support: 9VDC lithium battery slot for continuous monitoring during power outages.
Compatibility with Different Sensors: Float switch, pressure switch, or any "dry" type sensor can be used.
Auxiliary Contacts: Useful for connection to building automation systems and phone dialers.
Optional Pump Terminal Block: Allows integrating pump power, pump connections, and pump switch.
How It Works:
Powering the System: Connect the system to a 120VAC or 240VAC power source. Green LEDs will illuminate to indicate power status.
Alarm Activation: The alarm activates visually and audibly when the float switch or other sensor type contact is activated. The alarm condition continues until the sensor is deactivated.
Alarm Indication: The red LEDs flash and the buzzer pulses to signal an alarm condition. Auxiliary contacts also activate during this time.
Silencing the Alarm: Press and hold the touch button to silence the buzzer while the alarm LEDs continue flashing.
Alarm Reset: The silence condition will reset when the sensor deactivates and the alarm will automatically reset for the next cycle.
System Integrity Testing: Conduct monthly tests to ensure the system is functioning correctly.
Specifications
Primary Power
120VAC, 50/60 Hz
Power
1.4 Watts maximum (alarm condition)
Circuit board secondary power
9V DC, (1) standard 9V battery (not included)
Auxiliary contacts
120V AC, 1 mA minimum (signaling device)
Field connection sensor
9-10V DC, 1 mA minimum (signaling device)
LEDs
Green (power and zone indicator), Red (alarm condition and low battery)
Buzzer
95 dB at 10 feet
Enclosure
Thermoplatic 4 x 4 x 3 (inches). Type 4X, Outdoor. Lockable latch.
Certifications
CSA (US and Canada), FCC Part 15 (US and Canada)
Warranty